Home > Products > Salt Spray Chambers >
Model:108L/270L/412L/663L/816L/1080
Apply to:NSS,SS,ASS,CASS
Application:Hardware,Auto Parts,Construction Materials,Fastener
Overview
Lenpure Salt Spray Test Chamber could evaluate the anti-corrosion ability of materal and material coating , make a comparsion about the product techniques and quality of similar coating and products , It be used to test the electronic elements, and me
Feature
? Imported reinforced hard PP plates with smooth and flat surface
? Imported transparent impact-resistant plates as observe window
? All pipe is anti-corrosion can be used 15years .
? Adopt water seal method to prevent leakage of salt spray.
? With air pressure cylinder for convenient operation.
? Independent heating system , fast speed , temperature and humidity are evenly distributed
? Equipped with automatic demisting device
? Fault alarm and resolution remind function
? Power failure protection function
? Self-diagnosis function
? Calendar timing function
? Tri-color Indicator and EMO (Emergency-off Switch) available
Test Standards
ASTM B117/G85, BS 3900 F4/F9 , DIN 50-021 , ISO 9227 , IEC 68-2 , JIS H8502
This test equipment comply with above test standards (but not limited to):
Model
|
Volume (L)
|
Temperature Range
(°C) |
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-108-RY
|
108
|
RT+5°C ~ 55°C
|
1.5kW
|
450*600*450
|
780*1140*1050
|
LRHS-270-RY
|
270
|
1.8kW
|
600*900*500
|
960*1460*1150
|
|
LRHS-412-RY
|
412
|
4.0kW
|
750*1100*500
|
1100*1730*1240
|
|
LRHS-663-RY
|
663
|
5.0kW
|
850*1300*600
|
1230*2150*1410
|
|
LRHS-816-RY
|
816
|
6.0kW
|
850*1600*600
|
1230*2450*1460
|
|
LRHS-1080-RY
|
1080
|
6.5kW
|
900*2000*600
|
1280*2850*1460
|
|
Basic Specification | |||||
Performance
|
Temperature Range | RT+5°C ~ 55°C | |||
Air Saturator | RT+10°C ~ 70°C | ||||
Temperature Fluctuation | ±0.5°C | ||||
Temperature Uniformity | ≤ 2.0°C | ||||
Salt fog fall-out Rate | 1~2ml/80 cm².h(Ave in 16 hours) | ||||
Air Pressure | 2.00±0.01(kg/cm²) | ||||
Spray Method | Optional continuous/periodic test time: 1~9999 H、M、S (Adjustable) | ||||
Period time | 1~99 H , M , S (Adjustable) | ||||
Test specimen shelf | Test specimen shelf can meet the requirements of 15℃~30℃ tilt test | ||||
Material
|
Chamber material | Be made of imported reinforced hard PP plates with smooth and flat surface | |||
Saturated air cylinder | Made of imported high-quality mirror-finished stainless steel plates (SUS304) | ||||
Pipe | Reinforced fluorosilicone rubber tube | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window |
Multi-la |
||||
Control System
|
breaker | Schneider miniature circuit breaker | |||
Heater | Steipped Nickel-chromium Wire Heater | ||||
Controller |
P.I.D + S.S.R system. Have the function of automatic calculus, and can revise temperature & humidity change conditions to realize more accurate and stable temperature & humidity control. |
||||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Standard Configuration | Round stick , V-shaped sample shelf , Glass nozzle , Funnel , Metering cylinder , Flexible pipe | ||||
Safety Protection | Power leakage protection, Low water level protection, over-load or over-current protection/Dry burning protection. | ||||
Voltage | AC220V/380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85% R.H |